Sensaphone STATIONSitter Pump Control

Ordering Information

Sensaphone StationSitter
FGD-8300
MSRP: $1,090.00

StationSitter with NEMA-4X Solid Door
FGD-8300-SD
MSRP: $1,435.00

Accessories

Accessory Wire
FGD-0010
MSRP: $6.00

ISOTEL Surge Protector
FGD-0023
MSRP: $100.00

External Microphone Attachment
FGD-0057
MSRP: $30.00

J Type Thermocouple/4-20mA Converter
FGD-0220
MSRP: $349.00

StationSitter 5AH Battery
FGD-8310
MSRP: $55.00

Monitoring Sensors

Magnetic Reed Switch
FGD-0006
MSRP: $10.00

Infra-Red Motion Detector
FGD-0007
MSRP: $79.00

Spot Water Detector
FGD-0013
MSRP: $90.00

Temp Alert
FGD-0022
MSRP: $65.00

Humidistat
FGD-0027
MSRP: $40.00

Smoke Detector 110VAC
FGD-0049
MSRP: $55.00

Smoke Detector 110VAC with Battery backup
FGD-0049-B
MSRP: $65.00

Humidity 4-20mA Transmitter
FGD-0052
MSRP: $249.00

PowerOut Alert MODEL PS-110
FGD-0054
MSRP: $59.00

Zone Water Detector
FGD-0056
MSRP: $135.00

Tipping Bucket Rain Gauge
FGD-0061
MSRP: $140.00

Extra 10' Water Detection Rope
FGD-0063
MSRP: $70.00

Remote Temperature Sensor 2.8K
FGD-0100
MSRP: $20.00

2.8K Weatherproof Temperature
FGD-0101
MSRP: $30.00

10K Weatherproof Temperature
FGD-0102
MSRP: $30.00

10K Indoor Decorator Zone
FGD-0103
MSRP: $40.00

10K Outdoor Air Weatherproof
FGD-0104
MSRP: $70.00

10K Immersion Temperature
FGD-0105
MSRP: $60.00

Float Switch
FGD-0222
MSRP: $39.00


Product Quick Links

Features & Specifications



Features
ADVANCED CAPABILITIES
  • Eight universal inputs, configurable as Normally Open, Normally Closed, Temperature, or 4-20mA.
  • Easy-to-install with fully automatic input configuration. NO INPUT JUMPERS!
  • Scaleable range on 4-20mA analog inputs
  • Programmable recognition time for all inputs
  • Internal sensor calibration for all inputs
OUTPUTS
  • One output channel for manual or automatic control from alarms
  • Two additional outputs for duplex pump control
PUMP CONTROL
  • Built-in Pump Controller runs independently from alarm monitoring
  • Control logic for Fill or Drain applications
  • Pump control works with analog level sensor, or from float switches
NOTIFICATION
  • Eight phone numbers for alarm notification
  • Custom voice messages for the ID and ALL monitored zones
  • Text based alarm messages to alphanumeric pagers, and cell phones
  • Dial out test function to simulate and verify alarm notification
  • Individual user acknowledgement codes for tracking alarm activity
LOCAL ACCESS
  • Keypad and speaker for local programming
  • LED status indicators for all inputs and outputs, Battery, Power, Phone, and Pump Control Mode
  • Password protected keypad to restrict local programming access
  • Detailed alarm history with optional 30-minute snapshot history of all zones
REMOTE ACCESS
  • Automatic Web status option, free for first year
  • Detailed alarm history with optional hourly snapshot history of all zones
OTHER
  • High sound alarm with remote listen-in
  • Packaged in a panel mount enclosure with built-in mounting tabs
  • NEMA-4X enclosure optional
  • Superior lightning protection
  • Three year warranty

    • ENVIRONMENTAL INPUTS 
    • Number of Zones 
    • 8
    • Zone Connector 
    • terminal block
    • Zone Types 
    • N.O./N.C. contact, 2.8K and 10K thermistor (-20 to 150 deg F), and 4-20mA (-10,000 to 10,000)
    • Zone characteristics 
    • 10K. to 5V (temperature/contact) or 237 Ohms to ground (4-20mA)
    • A/D Converter Resolution 
    • 10 bits ±2 LSB
    • Zone Protection 
    • Gas discharge tubes, PTC fuses, and fast acting diode clamps

    • MICROPHONE 
    • Internal 
    • for recording custom voice messages
    • External(optional) 
    • For listening-in to on-site sounds and high sound level alarms
    • Mic Connector 
    • terminal block
    • Mic Type 
    • Electret Condenser
    • Mic Impedance 
    • 2.2K

    • PHONE INTERFACE 
    • Terminals 
    • connection to a two-wire analog telephone line
    •  
    • (8) Zone Alarms, Sound, Power, Battery OK, Phone in Use, Output On, and System On

    • LED INDICATORS 

    • PUMP CONTROL INPUTS 
    • Level Sensor 
    • Optically isolated 4–20mA input for connecting to a well-level transducer.
    • Float Inputs (3) 
    • Optically isolated dry contact inputs for connecting to float switches

    • RELAY OUTPUT 
    • 2A 120VAC/2A 24VDC: 
    • Programmable for duplex alternating pump control in Fill or Drain mode

    • PUMP OUTPUTS (2) 

    • POWER SUPPLY 
    • Power Supply 
    • 120VAC/12VAC 60Hz 10W wall plug-in transformer
    • Power Consumption 
    • 5 Watts
    • Power Protection 
    • Metal Oxide Varistor
    • Battery Backup 
    • 12V rechargeable (optional)
    • 24V Output 
    • 24VDC 40mA max.

    • ENVIRONMENTAL 
    • Operating Temperature 
    • 32-122 deg F (0-50 deg C)
    • Operating Humidity 
    • 0-90% RH non-condensing
    • Storage Temperature 
    • 32-140 deg F

    • PHYSICAL 
    • Dimensions 
    • 10.5"h x 8.3"w x 1.8"d
    • Weight 
    • 3.5 lbs
    • Enclosure 
    • Aluminum housing with integral mounting flanges for wall or panel installation.


Not sure what product is best for your application?